COVID-19 impacts us all in unexpected ways - If you're still in the lab or working at home please let us know how we can help - Contact Us

If I use a crRNA pool, what final concentration of crRNA should I use?

We recommend using the same final concentration of the pool as the individual crRNAs. For standard transfection methods we have found the optimal crRNA: tracrRNA concentration to be 25 nM.