There are no delays on our products or support as a result of COVID-19. If there is a way we can assist you, we are here to help - Contact us

If I use a crRNA pool, what final concentration of crRNA should I use?

We recommend using the same final concentration of the pool as the individual crRNAs. For standard transfection methods we have found the optimal crRNA: tracrRNA concentration to be 25 nM.